6 Multi-Button
8-128
WindO/I-NV4 User’s Manual
Upload PLC Program
is selected.
*1 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F only
*2 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G/1P only
*3 HG2J-7U only
Source:
Specify the source PLC connected to the MICRO/I. The PLC type is configured in the
Project Settings
dialog box, on the
Communication Driver Network
tab. For details, refer to Chapter 4 “3.4
Communication Driver Network Tab” on page 4-52.
Interface:
Select the communication interface in which the MICRO/I is connecting
to the upload source PLC from serial interface or Ethernet. For details,
refer to Chapter 4 “Interface Configuration” on page 4-35.
If serial interface is selected for
Interface
.
Slave Number:
Specify the slave number of the upload source PLC (0 to 31).
External Device Name:
The name of the specified PLC is displayed here.
If
Ethernet
is selected for
Interface
.
Select from the following method:
Specify External Device ID: Specify the External Device ID (0 to 31) of the upload source PLC. This is
the External Device ID number set in the
Project Settings
dialog box,
on the
Communication Driver Network
tab.
External Device Name:
The name of the specified PLC is displayed here.
Specify IP Address:
Specify the IP address and port number of the upload source PLC.
Destination: Specify where to save the PLC program uploaded from the PLC connected to the MICRO/I. Select the
type of external memory:
SD Memory Card
USB Flash Drive
USB1
or
USB2
Location: Specify the location of the folder where the uploaded PLC program will be saved. The
maximum number is 247 characters. Only alphanumeric characters and symbols can be
used. Path delimiters and characters that cannot be used vary based on the model.
Example: To save program to the folder “Uploaded_Program” in an external memory
device:
Uploaded_Program
Model
HG2J-7U
HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G/1P
Delimiter
Characters that cannot be used
" # $ & ' ( ) * : ; < > ? \ ` | ~
" * : ; < > ? |
/
\
A uploaded PLC program using the Data Transfer function is saved as a ZLD Project File(.zld).
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...