WindO/I-NV4 User’s Manual
3-65
5 User Communication
3
Co
m
m
un
ica
tio
n
■
Variable
Select this check box to store data up to either
Constant (Character)
data, or
Constant (Hexadecimal)
data from
the beginning of the received data in a device. Stores data of the size specified under
Words
.
When the stored data is smaller than the size specified under
Words
, the values of all remaining devices will stored 0.
When the check box is not selected, the amount of data (bytes) stored is Number of bytes x Number of words.
Examples: Device address for receive command data
Example 1
When the trigger condition is satisfied, the received data is stored in device addresses in the following order.
Example 2
When the trigger condition is satisfied, the received data is stored in device addresses in the following order.
3231h
LDR100:
3433h
LDR101:
0000h
LDR102:
1
(31h)
Value of Device Address
2
(32h)
3
(33h)
4
(34h)
Number of specified words: 3
Number of words for stored data: 2
The stored data is smaller than the size specified for Words.
No
conversion
Stored data
Insufficient by 1 word
0 is stored.
When the
Variable
check box is selected, observe the following points.
• When data is set expect for the end of a command, set
Constant (Character)
data or
Constant
(Hexadecimal)
data following
Device Address
data.
• When there is no data stored in the device address, all of the values of device addresses specified under
Words
will be 0.
• The maximum amount of the received data stored in the device address is Number of bytes x Number of
words.
Item
Setting
Conversion Type
No conversion
Device Address
LDR100
Use Reference Device Address
OFF
Storage Method of data
from Upper byte
Number of bytes
1
Words
3
Variable
OFF
Item
Setting
Conversion Type
No conversion
Device Address
LDR100
Use Reference Device Address
OFF
Storage Method of data
from Lower byte
Number of bytes
2
Words
2
Variable
OFF
3100h
LDR100:
3200h
LDR101:
3300h
LDR102:
No conversion
1
(31h)
Upper
Lower
Value of Device Address
0
(00h)
2
(32h)
0
(00h)
3
(33h)
0
(00h)
Received data
1
(31h)
2
(32h)
3
(33h)
Order of reception
Words: 3
from Upper byte
1 byte
from Lower byte
2 bytes
3231h
LDR100:
3433h
LDR101:
No conversion
2
(32h)
Upper
Lower
Value of Device Address
1
(31h)
4
(34h)
3
(33h)
Received data
1
(31h)
2
(32h)
3
(33h)
4
(34h)
Order of reception
Words: 2
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...