2 Line Chart
11-38
WindO/I-NV4 User’s Manual
■
Data
*3 This option can only be configured when
Device Address Display
is selected from
Chart Type
on the
General
tab.
Reference Device Address:
Specifies the start address number of the data to display on the chart.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1
Device Address Settings” on page 2-70.
The data size for the device addresses is 16 bits.
Updating and erasing the display is controlled by the lower 2 bits of the start address number value
(control status).
The number of values of device addresses to display is specified by the value of start address 1.
The values of device addresses from start address 2 are displayed on the chart.
Example: If
Reference Device Address
is set to D100, continuous device addresses are used starting
from D100. The used device addresses are as follows.
Line Type: Specifies the type of line. You can also specify it using the value of device address.
Value:
Selects the type of line from the following.
Solid
,
Dot
,
Dash
,
Long Dash
,
Long Dash Dot
,
Long Dash Dot Dot
Device Address: Specifies the line type using the value of device address.
Click
to display the Tag Editor. For the device address configuration procedure, refer
to Chapter 2 “5.1 Device Address Settings” on page 2-70.
Line type is as follows:
The line will be displayed with
Solid
when the value of device address is not 1 to 6 or
when the line width is not 1 (1 dot).
Bit 15
Bit 0
Bit 2
0 : Do not update
1 : Update
0 : Do not erase
1 : Erase
Reserved
D100
D101
D102
D103
D104
Control status (display operation)
Number of data to display values of device addresses on chart
Data to display values of device addresses on chart
(Start address number)
+1
+2
+3
+4
D106
D105
D104
D103
D102
D101
D100
10
50
20
60
10
1
5
D102
D103
Values of device addresses
Displayed chart
D104
D105
D106
0
20
40
60
80
100
-20
120
Preset Value
1
2
3
4
5
6
Line Type
Solid
Dot
Dash Long Dash
Long Dash
Dot
Long Dash
Dot Dot
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...