WindO/I-NV4 User’s Manual
10-55
2 Character Input
10
Da
ta
D
isp
la
ys
2.6 String Data Storage Method
The entered text is stored in the upper byte and lower byte according to the
Storage Method of String Data
setting.
Storage Method of String Data
is configured on the
System
tab in the
Project Settings
dialog box.
For details, refer to Chapter 4 “3.1 System Tab” on page 4-25.
Example 1:When the destination device address is “LDR100” and the entered text is “ABCDE”
• When
from Upper byte
is selected for
Storage Method of String Data
• When
from Lower byte
is selected for
Storage Method of String Data
Example 2:
When the destination device address is “LDR100” and the entered text is “
完了
”
• When
from Upper byte
is selected for
Storage Method of String Data
• When
from Lower byte
is selected for
Storage Method of String Data
2.7 Advanced Usage
●
Using the System Area
• When finished entering text by pressing
ENT
, 1 is written to the System Area 2 Character Input Setting Complete
bit (address 3, bit 5).
• When
CAN
is pressed, entry mode is canceled and 1 is written to the System Area 2 Character Input Setting Cancel
bit (address 3, bit 6). However, if the keypad is closed by pressing (close) on the popup screen's title
bar or another Character Input is pressed and selected before finished entering the text by pressing
ENT
, entry
mode is canceled and 1 is not written to the System Area 2 Character Input Setting Cancel bit (address 3,
bit 5).
• To clear the System Area 2 character input setting complete bit or the character input setting cancel bit, write 1 to
System Area 1 Character Input Setting Clear bit (address 1, bit 11). To automatically clear these bits when
the Character Input keypad is pressed in entry mode, select the
Clear Keypad bit in System Area
automatically
check box on the
System
tab in the
Project Settings
dialog box.
Device address
Stored value
Upper byte
Lower byte
LDR100
'A' = 41 (Hex)
'B' = 42 (Hex)
LDR101
'C' = 43 (Hex)
'D' = 44 (Hex)
LDR102
'E' = 45 (Hex)
0
NULL terminating character
Device address
Stored value
Upper byte
Lower byte
LDR100
'B' = 42 (Hex)
'A' = 41 (Hex)
LDR101
'D' = 44 (Hex)
'C' = 43 (Hex)
LDR102
0
'E' = 45 (Hex)
NULL terminating character
Device address
Stored value
Upper byte
Lower byte
LDR100
8A (Hex)
AE (Hex)
'
完
'
LDR101
97 (Hex)
B9 (Hex)
'
了
'
LDR102
0
NULL terminating character
Device address
Stored value
Upper byte
Lower byte
LDR100
AE (Hex)
8A (Hex)
'
完
'
LDR101
B9 (Hex)
97 (Hex)
'
了
'
LDR102
0
NULL terminating character
When handling strings, 0 is written to the device as the NULL terminating character and treated as the end
of the string.
Содержание WindO/I-NV4
Страница 1: ...B 1701 16 User s Manual...
Страница 50: ...1 WindO I NV4 Specifications 2 18 WindO I NV4 User s Manual Baltic ANSI 1257 Cyrillic ANSI 1251...
Страница 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Страница 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Страница 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Страница 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Страница 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Страница 522: ...5 Key Button 8 102 WindO I NV4 User s Manual Password Input These keys switch the user on the Password Input Screen...
Страница 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Страница 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Страница 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Страница 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Страница 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Страница 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Страница 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Страница 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Страница 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Страница 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Страница 1694: ...5 HG1P 35 80 WindO I NV4 User s Manual 5 6 Dimensions Unit mm Cable Dimensions 191 169 56 70 6 51 55 7...
Страница 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...