2
SETTING UP THE IP1000C SYSTEM
2-16
About the VE-PG3 settings (Converter mode)
1. Enter the IP address of the IP1000C in the [Bridge Connection] field. (Example: 192.168.0.1)
Select the Voice Cording. (Example: G.711u Signaling)
[Port Settings] (menu) > [Bridge] (screen) (Example: Bridge1) > [Bridge Connection] (field)
L
Make sure the using port number for connection do not duplicate with another connection.
2. Set the Call Type (Example: Group) and enter the Destination ID (Example: 11) in the [Bridge
Communication] field.
For Full-Duplex telephone operation, set the “Priority Receive” item in the [Bridge Control] field to
“Disable.”
3. Click <Apply> at bottom of the screen. Then click <Connect> in the [Bridge Connection] field.
•The “Connection Status” item changes form “Not Connected” to “During Transmit.”
“Default Callee ID” item
is set to “Enable,” set the
Destination settings below.
After settings in this screen
are completed, click <Apply>.
Then click <Connect>.
Set the PTT control or Call
Control types according to
your requirements.
192.168.0.2
192.168.0.1
Sales2
00002
Sales1
00001
Seles group1
00011
Extension number 2001
Extension number 500
IP1000C
VE-PG3
IP100H
Wireless
access point
Bridge connection
IP phone
(RoIP Gateway)
3. Bridge connection and Caller settings