4
ABOUT THE SETTING SCREEN
4-134
9. [Common Settings] Menu
[Common Settings]–[Profile]
■
Profile
27
TalkBack Lock �����
Select whether the Talk Back Lock function “Disable” or “Enable.”
(Default: Enable)
•
Enable
After a call is finished and the WLAN transceiver returns to the
standby mode, if it is received another call in the Talk back timer,
it accepts to receive when higher priority level call is received, or
refuses same or lower priority level call is received than the finished
call.
After the Talk back timer has passed, a new call can be received.
•
Disable
Accepts to receive a new call after your current call is finished.
28
TOT ����������
Select whether or not the WLAN transceiver uses the Time-out timer.
(Default: Disable)
L
When “Enable” is selected, the “TOT Timer,” “Penalty Timer,” “TOT Beep,”
“TOT on Telephone Call” items are displayed.
L
This function works when the WLAN transceiver’s PTT switch has
accidentally been held down.
29
TOT Timer �������
Set the Time-out timer to between 11 and 600 seconds.
The this timer limits the WLAN transceiver’s continuous transmission.
(Default: 180 (seconds))
30
Penalty Time ������
Set the TOT Penalty time to between 1 and 600 seconds.
After the TOT timer period ends, the TOT Penalty timer starts and
inhibits the user from transmitting during the penalty period.
(Default: 30 (seconds))
(This is only an example.)
27
28
29
30
31
32