Note:
See
“System
replaceable
units”
on
page
144
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
166-070-000
System
Management:
Failed
(Unable
to
communicate
with
RSA.
It
may
be
busy.
Run
the
test
again.)
1.
Flash
latest
levels
of
firmware
(BIOS,
service
processor,
diagnostics)
2.
Rerun
diagnostic
test.
3.
Correct
other
error
conditions
(including
failed
system
management
tests
and
items
logged
in
Remote
Supervisor
Adapter
II
SlimLine
system-error
log
and
BMC
log)
and
retry.
4.
Disconnect
all
server
and
option
power
cords
from
server,
wait
30
seconds,
reconnect,
and
retry.
5.
Remote
Supervisor
Adapter
II
SlimLine.
166-198-000
System
Management:
Aborted
(Unable
to
communicate
with
RSA.
It
may
be
busy.
Run
the
test
again.)
1.
Run
the
diagnostic
test
again.
2.
Correct
other
error
conditions
and
retry.
These
include
other
failed
system
management
tests
and
items
logged
in
the
system-error
log
of
the
optional
Remote
Supervisor
Adapter
II
SlimLine.
3.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
4.
Remote
Supervisor
Adapter
II
SlimLine,
if
installed.
5.
System
board.
166-260-000
System
Management:
Failed
(Restart
RSA
error.
After
restarting,
RSA
communication
was
lost.
Unplug
and
cold
boot
to
reset
RSA.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
3.
Remote
Supervisor
Adapter
II
SlimLine.
166-342-000
System
Management:
Failed
(RSA
adapter
BIST
indicate
failed
tests.)
1.
Ensure
the
latest
firmware
levels
for
Remote
Supervisor
Adapter
II
SlimLine
and
BIOS
are
installed.
2.
Disconnect
all
server
and
option
power
cords
from
server,
wait
30
seconds,
reconnect,
and
retry.
3.
Remote
Supervisor
Adapter
II
SlimLine.
166-400-000
System
Management:
Failed
(BMC
self
test
result
failed
tests:
x
where
x
=
Flash,
RAM,
or
ROM.)
1.
Reflash
or
update
firmware
for
BMC.
2.
System
board.
166-404-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
Power
backplane
4.
System
board.
166-406-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
SCSI
cable.
4.
SCSI
backplane.
5.
System
board.
Chapter
6.
Symptom-to-FRU
index
119
Содержание xSeries 236 8841
Страница 1: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 20: ...10 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 96: ...86 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 152: ...142 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 160: ...150 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 173: ...Appendix B Safety information 163...
Страница 174: ...164 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 175: ...Appendix B Safety information 165...
Страница 176: ...166 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 177: ...Appendix B Safety information 167...
Страница 178: ...168 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 179: ...Appendix B Safety information 169...
Страница 189: ...Appendix B Safety information 179...
Страница 190: ...180 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 191: ...Appendix B Safety information 181...
Страница 192: ...182 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 196: ...186 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 207: ...W Web site compatible options iv DIMM specification 33 online publications 1 support iv weight 3 Index 197...
Страница 208: ...198 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 209: ......
Страница 210: ...Part Number 25K8114 1P P N 25K8114...