v
The server supports one optional ultra-slim SATA CD-RW/DVD-ROM optical
drive.
v
The server can support up to eight 2.5-inch hot-swap SAS/SATA drives, four
3.5-inch hot-swap SAS/SATA drives, or four 3.5-inch simple-swap SATA drives.
(see Supported SAS/SATA drive backplane configurations for the supported
configurations).
v
You can mix hot-swap SAS and SATA hard disk drives in the same server as
long as you do not mix drives on the same array.
v
The electromagnetic interference (EMI) integrity and cooling of the server are
protected by having all bays and PCI Express slots covered or occupied. When
you install a drive, save the EMC shield and filler panel from the bay in the
event that you later remove the device.
Installing a 2.5-inch hot-swap hard disk drive
The following notes describe the types of hard disk drives that the server supports
and other information that you must consider when you install a hard disk drive:
v
Depending on the model, the server supports up to eight or up to sixteen
2.5-inch SAS/SATA hot-swap hard disk drives in the hot-swap bays.
Note:
When using ServeRAID adapter M1015 to support more than sixteen
2.5-inch hard disk drives, the maximum number of RAID supported drives is 16.
All the other drives will remain JBOD (the drives are presented to the operating
system without a RAID configuration).
v
For a list of supported optional devices for the server, see http://
www.ibm.com/servers/eserver/serverproven/compat/us/
v
Inspect the drive and drive bay for signs of damage.
v
Make sure that the drive is correctly installed in the drive bay.
v
See the documentation for the ServeRAID adapter for instructions for installing
a hard disk drive.
v
All hot-swap drives in the server must have the same throughput speed rating;
using drives with different speed ratings might cause all drives to operate at the
speed of the slowest drive.
v
You do not have to turn off the server to install hot-swap drives in the hot-swap
drive bays. However, you must turn off the server when you perform any steps
that involve installing or removing cables.
To install a 2.5-inch hot-swap hard disk drive, complete the following steps:
1.
Read the safety information that begins “Safety” on page vii and “Installation
guidelines” on page 36
Attention:
Static electricity that is released to internal server components
when the server is powered-on might cause the server to halt, which might
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
2.
Unlock the left-side cover.
Note:
You must unlock the left-side cover to open or remove the bezel. When
you lock the left-side cover, it locks both the cover and the bezel.
3.
Open the bezel (see “Removing the bezel” on page 331)
4.
Remove the filler panel, if one is present.
70
System x3300 M4 Type 7382: Installation and Service Guide
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...