Table 18. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80010b01-1401xxxx
80010b01-1402xxxx
Sensor CPU
n
VR
Temp going high
(upper
non-recoverable) has
asserted. (
n
=
microprocessor
number)
Error
An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
80010701-2d01xxxx
Numeric sensor PCH
Temp going high
(upper non-critical)
has asserted.
Warning
An upper
non-critical sensor
going high has
asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
80010901-2d01xxxx
Numeric sensor PCH
Temp going high
(upper critical) has
asserted.
Error
An upper critical
sensor going high
has asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
80010b01-2d01xxxx
Numeric sensor PCH
Temp going high
(upper
non-recoverable) has
asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
81010701-2d01xxxx
Numeric sensor PCH
Temp going high
(upper non-critical)
has deasserted.
Info
An upper
non-critical sensor
going high has
deasserted.
No action; information only.
81010901-2d01xxxx
Numeric sensor PCH
Temp going high
(upper critical) has
deasserted.
Info
An upper critical
sensor going high
has deasserted.
No action; information only.
81010b01-2d01xxxx
Numeric sensor PCH
Temp going high
(upper
non-recoverable) has
deasserted.
Info
An upper
non-recoverable
sensor going high
has deasserted.
No action; information only.
80010204-1d01xxxx
80010204-1d02xxxx
80010204-1d03xxxx
80010204-1d04xxxx
80010204-1d05xxxx
80010204-1d06xxxx
80010204-1d07xxxx
80010204-1d08xxxx
80010204-1d09xxxx
80010204-1d0axxxx
80010204-1d0bxxxx
80010204-1d0cxxxx
Numeric sensor Fan
n
A Tach going low
(lower critical) has
asserted. (
n
= 1Aa,
1Ab, 2Aa, 2Ab, 3Aa,
3Ab)
Error
A lower critical
sensor going low
has asserted.
1.
Reseat the failing fan
n
, which is
indicated by a lit LED near the fan
connector on the system board.
2.
Replace the failing fan (see
“Removing the fan assembly” on
page 42 and “Replacing the fan
assembly” on page 412).
(
n
= fan number)
Chapter 4. Troubleshooting
175
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...