![IBM System x3300 M4 Скачать руководство пользователя страница 148](http://html2.mh-extra.com/html/ibm/system-x3300-m4/system-x3300-m4_installation-and-service-manual_4733442148.webp)
6.
Select the type of array that you want to create.
7.
Select
Select Drives
and use space key to select all the drives for your array.
8.
Select
Apply Changes
to create the array.
9.
When the prompt
Success
is displayed, select
OK
to continue.
10.
After the system auto skip to the next screen, select
Save Configuration
.
11.
When the prompt
Creating Virtual Drives will cause the data lost on
the associated Drives to be permanently deleted.
is displayed, use space
key to select
Yes
to continue.
12.
Select
OK
to continue.
13.
To initialize virtual disk, select
ServeRAID C105
→
Virtual Drive Management
→
Select Virtual Drive Operations
.
14.
Under
Virtual Drive Operation
, choose
Select Operation
. Select the type of
initialization you want to initialize.
15.
Select
Start Operation
.
16.
Select
Yes
to confirm.
17.
Select
OK
to continue.
18.
When the prompt
Success
is displayed, select
OK
.
Note:
1.
For further details on creating a software RAID array of hard disk drives,
please see the ServeRAID C105 documentation at http://www-947.ibm.com/
support/entry/portal/docdisplay?lndocid=MIGR-5089068.
2.
Some specific models may be shipped initially with four hard disk drives.
Configuration may be able to expand to eight hard disk drives via Features on
Demand (FoD). Please note that the server may need to be restarted to activate
the feature. For more information on Features on Demand (FoD), including
instructions for automating the activation and installation of the activation key
by using IBM ToolsCenter or IBM Systems Director, see the IBM Features on
Demand User's Guide at https://www-304.ibm.com/systems/x/fod/index.wss
under the Help section.
3.
Software RAID is not supported in VMware 5 and VMware 4.1.
4.
Software RAID is not supported in legacy configuration.
5.
In order to install the legacy OS in the software RAID, you have to set the
SCU
Controller
as the first device in the option ROM execution order.
130
System x3300 M4 Type 7382: Installation and Service Guide
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...