Table 19. DSA messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
405-907-xxx
Ethernet
Device
Test LEDs
Failed
1.
Make sure that the component firmware
is at the latest level. The installed
firmware level is shown in the DSA event
log in the Firmware/VPD section for this
component. For more information, see
“Updating the firmware” on page 111.
2.
Run the test again.
3.
Replace the component that is causing the
error. If the error is caused by an adapter,
replace the adapter. Check the PCI
Information and Network Settings
information in the DSA event log to
determine the physical location of the
failing component.
4.
If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Troubleshooting by symptom
Use the troubleshooting tables to find solutions to problems that have identifiable
symptoms.
If you cannot find a solution to the problem in these tables, see “DSA messages”
on page 228 for information about testing the server and “Running the DSA
Preboot diagnostic programs” on page 153 for additional information about
running DSA Preboot program that is stored in integrated USB memory on the
server. For additional information to help you solve problems, see “Start here” on
page 139.
If you have just added new software or a new optional device and the server is
not working, complete the following steps before you use the troubleshooting
tables:
1.
Check the system-error LED on the operator information panel; if it is lit, check
the light path diagnostics LEDs (see Light path diagnostics).
2.
Remove the software or device that you just added.
3.
Run IBM Dynamic System Analysis (DSA) to determine whether the server is
running correctly (for information about using DSA, see “DSA messages” on
page 228.
4.
Reinstall the new software or new device.
276
System x3300 M4 Type 7382: Installation and Service Guide
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...