v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
Description
Action
S.3818004 [S.3818004] The CRTM flash
driver could not successfully
flash the staging area. A failure
occurred.
CRTM Update Failed.
1.
Run the Setup utility, select
Load
Default Settings
, and save the
settings.
2.
Recover the server firmware.
W.3818005 [W.3818005] The CRTM flash
driver could not successfully
flash the staging area. The
update was aborted.
CRTM Update Aborted.
1.
Run the Setup utility, select
Load
Default Settings
, and save the
settings.
2.
Recover the server firmware.
S.3818007 [S.3818007] The firmware image
capsules for both flash banks
could not be verified.
CRTM image capsule could not
be verified.
1.
Run the Setup utility, select
Load
Default Settings
, and save the
settings.
2.
Recover the server firmware.
W.3938002 [W.3938002] A boot
configuration error has been
detected.
Boot Configuration Error.
1.
Run the Setup utility, select
Load
Default Settings
, and save the
settings.
2.
Recover the server firmware.
Integrated management module II (IMM2) error messages
The following table describes the IMM2 error messages and suggested actions to
correct the detected problems.
For more information about IMM2, see the
Integrated Management Module II User's
Guide
at http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-
5086346.
Table 18. IMM2 error messages
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Event ID
Message
Severity
Description
Action
Temperature and fan messages
80010701-0701xxxx
Numeric sensor
adapter Ambient
Temp going high
(upper non-critical)
has asserted.
Warning
An upper
non-critical sensor
going high has
asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
Chapter 4. Troubleshooting
173
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...