Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
Description
Action
I.2018002
[I.2018002] The device found at
Bus % Device % Function %
could not be configured due to
resource constraints. The
Vendor ID for the device is %
and the Device ID is %.
OUT_OF_RESOURCES (PCI
Option ROM).
1.
Run the Setup utility (see “Using
the Setup utility” on page 115).
Select
Startup Options
from the
menu and modify the boot
sequence to change the load order
of the optional-device ROM code.
2.
Informational message that some
devices might not be initialized.
3.
See retain tip H197144
(http://www-947.ibm.com/
support/entry/portal/
docdisplay?lndocid=migr-5084743)
for more information.
I.2018003
[I.2018003] A bad option ROM
checksum was detected for the
device found at Bus % Device
% Function %. The Vendor ID
for the device is % and the
Device ID is %.
ROM CHECKSUM ERROR.
1.
Check the riser-card LEDs.
2.
Reseat all affected adapters and
riser cards.
3.
Move the affected adapter to a
different slot.
4.
Update the PCI adapter firmware.
5.
Replace the affected adapters and
riser cards.
S.3020007 [S.3020007] A firmware fault
has been detected in the UEFI
image.
Internal UEFI Firmware Fault
Detected, System halted.
1.
Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this error.
2.
Recover the server firmware.
3.
(Trained technician only) replace
the system board.
S.3028002 [S.3028002] Boot permission
timeout detected.
Boot Permission Negotiation
Timeout.
1.
Check the IMM2 error messages
for communication errors and
follow the actions.
2.
Restart the server.
3.
If the problem remains, contact
your IBM service representative
for support.
S.3030007 [S.3030007] A firmware fault
has been detected in the UEFI
image.
Internal UEFI Firmware Fault
Detected, System halted.
1.
Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this error.
2.
Recover the server firmware.
3.
(Trained technician only) Replace
the system board.
168
System x3300 M4 Type 7382: Installation and Service Guide
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...