If the yellow hard disk drive status LED is lit continuously, that drive is
faulty and must be replaced. If the green hard disk drive activity LED is
flashing, the drive is being accessed.
b.
If the server is configured for RAID operation through an optional
ServeRAID adapter, you might have to re-configure your disk arrays after
you install hard disk drives. See the ServeRAID documentation on the IBM
ServeRAID
Support
CD for additional information about RAID operation
and complete instructions for using ServeRAID Manager
8.
Close the bezel.
9.
Lock the left-side cover.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 104
Removing a 3.5-inch hot-swap hard disk drive:
Before removing a 3.5-inch hot-swap hard disk drive, read the following
information:
v
Inspect the drive tray for signs of damage.
v
To maintain proper system cooling, do not operate the server for more than 10
minutes without either a drive or a filler panel installed in each drive bay.
v
You do not have to turn off the server to install hot-swap drives in the hot-swap
drive bays.
To remove a 3.5-inch hot-swap hard disk drive, complete the following steps.
1.
Read the safety information that begins “Safety” on page vii and “Installation
guidelines” on page 36
Attention:
Static electricity that is released to internal server components
when the server is powered-on might cause the server to halt, which might
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
2.
Unlock and remove the left-side cover.
Note:
You must unlock the left-side cover to open or remove the bezel. When
you lock the left-side cover, it locks both the cover and the bezel.
3.
Open the bezel (see “Removing the bezel” on page 331).
4.
Remove the filler panel, if one is present.
5.
Push the orange release latch of the drive tray and take the 3.5-inch hard disk
drive out of the drive bay of the server.
Chapter 6. Removing and replacing components
345
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...