Serial-device problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 5, “Parts listing, IBM System x3300 M4 Type 7382,” on page 303 to check if a component is a
consumable, structural, or FRU part.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Symptom
Action
The number of serial ports that
are identified by the operating
system is less than the number
of installed serial ports.
1.
Make sure that:
v
Each port is assigned a unique address in the Setup utility and none of the
serial ports is disabled.
v
The serial-port adapter (if one is present) is seated correctly.
2.
Reseat the serial port adapter.
3.
Replace the serial port adapter.
A serial device does not work.
1.
Make sure that:
v
The device is compatible with the server.
v
The serial port is enabled and is assigned a unique address.
v
The device is connected to the correct connector (see “Connecting the
cables” on page 108).
2.
Reseat the following components:
a.
Failing serial device
b.
Serial cable
3.
Replace the components listed in step 2 one at a time, in the order shown,
restarting the server each time.
4.
(Trained technician only) Replace the system board.
ServerGuide problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 5, “Parts listing, IBM System x3300 M4 Type 7382,” on page 303 to check if a component is a
consumable, structural, or FRU part.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Symptom
Action
The
ServerGuide Setup and
Installation
CD will not start.
1.
Make sure that the server supports the ServerGuide program and has a
startable (bootable) CD or DVD drive. See the readme file that is part of the
ISO image at http://www-947.ibm.com/systems/support/supportsite.wss/
docdisplay?brandind=5000008&lndocid=TOOL-CENTER.
2.
Make sure that you burned the CD or DVD from an image (do not burn the
CD or DVD ISO file as a data disk)
3.
Make sure that you burn the CD or DVD as
disk at once
(not track at once).
4.
If the startup (boot) sequence settings have been changed, make sure that the
CD or DVD drive is first in the startup sequence.
5.
If more than one CD or DVD drive is installed, make sure that only one drive
is set as the primary drive. Start the CD from the primary drive.
The MegaRAID Storage
Manager program cannot view
all installed drives, or the
operating system cannot be
installed.
1.
Make sure that the hard disk drive is connected correctly.
2.
Make sure that the SAS/SATA hard disk drive cables are securely connected.
294
System x3300 M4 Type 7382: Installation and Service Guide
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...