Table 18. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0813-2582xxxx
An Uncorrectable
Bus Error has
occurred on system
%1.(%1 =
CIM_ComputerSystem.ElementName)
Error
A bus
uncorrectable error
has occurred.
(Sensor = Critical
Int PCI)
1.
Check the system-event log.
2.
Check the PCI LED. See more
information about the PCI LED in
Light path diagnostics LEDs.
3.
Remove the adapter from the
indicated PCI slot.
4.
Check for a server firmware update.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5.
(Trained technician only) Replace
the system board (see “Removing
the system board” on page 428 and
“Replacing the system board” on
page 430).
806f0125-0B01xxxx
806f0125-0B02xxxx
The entity of PCI
riser has been
detected absent for
PCI
n
. (
n
= PCI slot
number)
Info
The entity of PCI
riser
n
has been
detected absent. (
n
= PCI slot number)
No action; information only.
General messages
80030006-2101xxxx
Sensor Sig Verify Fail
has deasserted.
Info
An implementation
has detected a
sensor has
deasserted.
No action; information only.
80030012-2301xxxx
Sensor OS RealTime
Mod has deasserted.
Info
Sensor OS
RealTime Mod has
deasserted.
No action; information only.
80050108-0a01xxxx
80050108-0a02xxxx
Sensor has indicated
limit exceeded.
Info
This message is for
the use case when
an implementation
has detected a
Sensor limit was
exceeded.
No action; information only.
80070114-2201xxxx
Sensor TPM Lock /
TPM Phy Pres Set
has transitioned from
normal to
non-critical state.
Warning
An implementation
has detected a
sensor transitioned
to non-critical from
normal.
1.
This is a UEFI detected event. The
UEFI diagnostic code for this event
can be found in the logged IMM
message text. Please refer to the
UEFI diagnostic code in the "UEFI
diagnostic code" section of the Info
Center for the appropriate user
response.
204
System x3300 M4 Type 7382: Installation and Service Guide
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...