Power problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 5, “Parts listing, IBM System x3300 M4 Type 7382,” on page 303 to check if a component is a
consumable, structural, or FRU part.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Symptom
Action
The power-control button does
not work, and the reset button
does not work (the server does
not start).
Note:
The power-control button
will not function until
approximately 1 to 3 minutes
after the server has been
connected to ac power.
1.
Make sure that the left-side cover is closed and latched correctly.
2.
Make sure that the left-side cover/power cut-off switch cable is seated
correctly.
3.
Make sure that the power-control button on the server is working correctly:
a.
Disconnect the server power cords.
b.
Reconnect the power cords.
c.
Reseat the operator information panel cables, and then repeat steps 3a and
3b.
v
If the server starts, reseat the operator information panel. If the problem
remains, replace the operator information panel.
4.
Make sure that the reset button is working correctly:
a.
Disconnect the server power cords.
b.
Reconnect the power cords.
c.
Reseat the operator information panel cable, and then repeat steps 3a and
3b.
v
If the server starts, replace the operator information panel.
v
If the server does not start, go to step 5.
5.
Make sure that:
v
The power cords are correctly connected to the server and to a working
electrical outlet.
v
The type of memory that is installed is correct.
v
The DIMMs are fully seated.
v
The LEDs on the power supply do not indicate a problem.
v
The microprocessors are installed in the correct sequence.
6.
Reseat the following components:
a.
DIMMs
b.
Power supplies
7.
Replace the components listed in step 6 one at a time, in the order shown,
restarting the server each time.
8.
If you just installed an optional device, remove it, and restart the server. If the
server now starts, you might have installed more devices than the power
supply supports.
9.
See “Power-supply LEDs” on page 21.
10.
See “Solving undetermined problems” on page 298.
The server does not start.
1.
Check the power LED on the system board. See “System-board LEDs” on page
33 for the LED location.
2.
Reseat the power supply.
3.
Replace the power supply.
The server does not start.
(Continued)
Chapter 4. Troubleshooting
289
Содержание System x3300 M4
Страница 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Страница 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Страница 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 405: ...Chapter 6 Removing and replacing components 387...
Страница 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Страница 469: ......
Страница 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...