When these error latches are set by errors (not forced by diagnostics) they are una-
vailable to the control programs which reside in main storage.
After error information collection, MOSS may cause a re-IPL to take place.
Program Errors
Storage Protect Program Execution Error: Storage protect keys mismatch or
read-only key violation during a program storage instruction.
Address Exception Program Execution Error: Program attempt to read or write
uninstalled storage.
Storage Protect Instruction Fetch Error: Attempt to execute an instruction
fetched from a storage area whose key did not match the program user key.
Address Exception Instruction Fetch Error: Attempt to execute an instruction
fetched from an uninstalled storage location.
Level 5 I/O Error: Attempt to perform an input or output instruction in program
level 5.
Invalid OP-Code: Attempt to execute an instruction with an OP-code that does
not compare to any of the 53 valid OP-codes, or input, or output instruction to
invalid external register addresses.
Handling
These errors result in an interrupt level 1 sent to the control program except if
already in program level 1 (in this case a CCU hard check condition occurs).
Error information can be obtained by the control program using the input X'7E'
instruction (see “Input Instructions” on page 2-25).
However, storage protect or address exception errors are unrecoverable in program
execution (load or store instruction) because, in some cases, the next instruction
will be executed before the interrupt to program level 1.
For details on DMA storage protect, see Chapter 5, “High Performance Trans-
mission Subsystem (HPTSS)” on page 5-1.
Adapters Interconnection Errors
IOC Adapter Bus Parity Error: Parity error detected when reading the IOC bus.
IOC Time-Out Error: Erroneous timing sequence on IOC interface.
IOC Adapter CCW Error: Invalid channel control word coming from the adapter.
IOC Storage Protect Error: Storage protect violation detected during an adapter-
initiated operation (AIO) write.
Chapter 2. Central Control Unit (CCU)
2-47
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...