MOSS BER
Table 11-9 (Page 3 of 6). MOSS BER Type 01 Summary
BER
ID
MOSS
Chk
code
BER
Add
Fld
Event Description
Recovery
or PGM
Action
ALERT
ALARM
05
F0
MOSS-scanner interface error
Hard re-IML KO, dump OK. Error detected by
MOSS levels 1 or 4, when communicating with a
scanner:
MCC status register 1, bit 6, at level 4
CCU to MOSS status A register X'11' bit 0, and
X'76' bits 0.6 or 0.7, at level 1)
MOSS
funct.
message
TSS:
6B
HPTSS:
72
TSS:
6B
HPTSS:
72
05
F0
MOSS-scanner interface error.
Hard re-IML KO, dump KO. Error detected by
MOSS levels 1 or 4, when communicating with a
scanner:
MCC status register 1, bit 6, at level 4
CCU to MOSS status A register X'11' bit 0, and
X'76' bits 0.6 or 0.7, at level 1.
MOSS
funct.
message
TSS:
66
HPTSS:
72
TSS:
66
HPTSS:
72
06
01
BER file deleted (via MOSS command)
File purged
NO
NO
06
02
BER stack overflow in MOSS storage.(MOSS main-
tains a 5K-bytes buffer to stack incoming BERs,
before logging on)
NO
NO
06
03
01
IPL complete with errors.
Some errors do not prevent the completion of IPL:
Scanner not IMLed successfully
Bad parameters passed by control program
Errors in CA monitoring task
Error, found on the diskette, which is not detri-
mental for the IPL
Console or console adapter error
Corresponding BERs are in the BER File. There is
a message on the console.
IPL com-
pletion
D1
D1
06
04
LAxx (Lines xxxx-yyyy) IML failed
6A
6A
06
05
05
NCP re-IPL end and no dump
MOSS creates this entry to end the re-IPL and gen-
erates the alert reporting the error which caused the
re-IPL.
CCU hardcheck BER as alert support (see Specific
Mechanism, page 11-12)
20
20
06
05
05
NCP re-IPL end and dump
MOSS creates this entry to end the re-IPL and gen-
erates the alert reporting the error which caused the
re-IPL.
CCU hardcheck BER as alert support (see Specific
Mechanism, page 11-12)
27
27
06
05
07
NCP re-IPL end and no dump.
MOSS creates this entry to end the re-IPL and gen-
erates the alert reporting the error which caused the
re-IPL.
CCU re-IPL on program request (see Specific Mech-
anism, page 11-12)
46
46
06
05
07
NCP re-IPL end and dump, and ABENDs : 910, 911,
930, 931.
MOSS creates this entry to end the re-IPL and gen-
erates the alert reporting the error which caused the
re-IPL.
CCU re-IPL on program request (see Specific Mech-
anism, page 11-12)
41
41
Chapter 11. Error Logging
11-35
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...