Single Multiplexer Card (SMUXA/B)
For LIC types 5 and 6 (DTE plus DCE functions):
The SMUXA is associated to the lower board.
The SMUXB is associated to the upper board.
SMUXA and SMUXB are slightly different in packaging (cable connector), but are functionally identical;
therefore, SMUXA of SMUXB will be referred to as SMUX cards.
SMUX Functions
The SMUX cards convert the serial Manchester-encoded bit stream into the LIC serial outbound bit stream
and, conversely, the serial inbound bit stream from the LICs into serial Manchester-encoded bit stream for
the FES.
┌──────┐
┌──────┐
Inbound
┌─────┐
│
│
Serial Link
│
├─────%───────┤ LIC │
│ FESA ├───────────────┤ SMUX ├─────5───────┤
│
│
│
│
│
Outbound
└─────┘
└──────┘
└──────┘
ð
1
│
│
│
ð
1
├─┐ │ ┌─┤
───┐
┌───┐
│ │ │ │ │
│
│
│
│ └─├─┘ │
└───┘
└───
│
│
│
Manchester encoding
On the serial link side:
Monitors the frames coming from the FESA.
Retrieves and decodes the Manchester-encoded information.
Detects the frame synchronization pattern and transmits sync pulses to the LICs.
Loads the information devoted to the SMUX into the proper register.
On the LIC bus side:
Monitors the serial information coming from the LICs.
Transmits it to the FESA after Manchester-encoding.
Sends the control information from the SMUX registers to the FESA.
In addition the SMUX provides:
A bit timing synchronized from the received data (PLO function)
Two functional clock signals to the LICs (synchronized from the outbound data flow)
Eight LIC reset commands (to isolate any LIC from the inbound data flow)
SMUX physical address, machine frame configuration, SMUX EC number and 'LIC5/6 present' indi-
cation
Error detection
Diagnostic facilities
1 MHz clock signal to the LICs for PKD operation
Four binary coded bits to LIC type 5 for transmit level setting (see transmit level hereafter).
Transmit Level
The transmit level is country-dependent.
The correct transmit level for a given country must be set at installation time by the CE each SMUX card
by means of four switches (0 to -15 dBm).
Chapter 4. Transmission Subsystem (TSS)
4-39
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...