CCU BER
NCP CCU BER Type 13
CCU BER Type 13 - Summary
Table 11-65 (Page 1 of 2). CCU BER Type 13 Summary
BER
ID
Abend
Code
(NCP)
Event Description
Recovery
or PGM
Action
ALERT
ALARM
32
0
Level 3 interrupt configuration check
Invalid level 3 interrupt (for example, CA interrupt
on a link-attached 3745.
NO
NO
32
0978
Level 3 interrupt configuration check (limit threshold)
NCP re-IPL
NO
NO
91
0
Unresolved level 1 interrupt, no bit in CA register X'E'.
NO
NO
91
0970
Unresolved level 1 interrupt (limit threshold)
NCP re-IPL
NO
NO
92
0971
Unresolved interrupted level when requested
Interrupt level not 2, 3, 4, 5 as per contents of X'79'
bits 1.0, 1.1, 1.2, 1.3.
NCP re-IPL
NO
NO
93
0972
Unexpected CCU hardcheck (CCU should have
stopped)
Not possible to reset X'77', bit 0.1, or
MOSS has not reset this bit after IPL.
NCP re-IPL
NO
NO
94
0973
Unexpected IPL request
Not possible to reset X'77' bit 0.0, or
MOSS has not reset this bit after IPL.
NCP re-IPL
NO
NO
95
0971
Invalid level 1 interrupted IAR (IN X'79')
NCP re-IPL
NO
NO
B1
0
Unresolved level 3 interrupt
NCP reading out X'77' does not find bit 1.0 ON (CA
level 3) and X'7F' bits 0.2, 0.6, 1.5 and 1.6 ON ( level 3
raised by MOSS diag, user, timer or PCI).
NO
NO
B1
0974
Unresolved level 3 interrupt (limit threshold
NCP re-IPL
NO
NO
C1
0
Unresolved level 4 interrupt
NCP reading out X'7F' does not find bits 0.3, 0.4, 0.7
and 1.7 ON (Level 4 interrupt raised by MOSS request
SVC, MOSS response SVC, PCI or SVC).
NO
NO
C1
0975
Unresolved level 4 interrupt (limit threshold)
NCP re-IPL
NO
NO
C2
0
Unresolved level 4 PCI interrupt
Level 4 PCI (X'7F' bit 0.7) and not wait state, but
no bytes are set in level 4 control block of NCP.
Mask used to set interrupt does not indicate
release, slowdown, dispatcher request
SVC interrupt, or mask indicates wait state plus
MOSS offline, outmail box, CRP request for MOSS
transfer, or MOSS request.
NO
NO
C2
0976
Unresolved level 4 PCI interrupt (limit threshold)
NCP re-IPL
NO
NO
C3
0
Hot/spurious level 4 PCI
Level 4 PCI latch (X'7F' bit 0.7) does not go OFF, after
a reset by output X'77' bit 1.6
NO
NO
C3
0977
Hot/spurious level 4 PCI (limit threshold)
NCP re-IPL
NO
NO
C4
0979
Unresolved level 4 SVC interrupt
Level 4 SVC interrupt (X'7F' bit 1.7) but CCU is in wait
state. Abend if hot SVC interrupt (X'7F' bit 1.7 still ON
after reset latch by Out X'77' bit 1.7).
NCP re-IPL
NO
NO
11-194
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...