MOSS BER
MOSS BERs Used With the IPL Application
The following BERs are used by MOSS in connection with an IPL application:
Note: (1) Non-blocking errors.
Table 11-8. MOSS BER Used With IPL Application
ID
Error code
Ext.
Description
Format.
06
03
06
05
05
08
08
09
01
01
05
07
05
07
IPL co errors (1)
IPL check
CCU hardcheck as alert support
Program request as alert support
CCU hardcheck as alarm support
Program request as alarm support
CLDP abend as alarm support
FoM6
"
F0M19
"
FoM9
FoM19
FoM10
20
01
IPL complete without errors
FoM21
21
01
IPL started
FoM23
MOSS BER Type 01 - Summary
Table 11-9 (Page 1 of 6). MOSS BER Type 01 Summary
BER
ID
MOSS
Chk
code
BER
Add
Fld
Event Description
Recovery
or PGM
Action
ALERT
ALARM
00
See MOSS-CHECK code for software error
See MOSS-CHECK code for hardware error
01
02
01
02
01
01
See MOSS 01 ID 01 field description
MOSS retry
NO
NO
01
02
See MOSS 01 ID 02 field description
MOSS retry
NO
NO
01
02
IOC operation error during MIOH (CCU to MOSS
status A register, X'11', bit 0)
MOSS retry
NO
NO
01
02
IOC operation error (limit threshold)
MOSS
down
NO
03
01
03
Adapter clock check (MCC status register 2, bit 4)
MOSS retry
NO
NO
01
03
Adapter clock check (limit threshold)
MOSS
down
NO
03
01
04
CCU clock check (MCC status register 2, bit 3)
MOSS retry
NO
NO
01
04
CCU clock check (limit threshold)
MOSS
down
NO
03
01
05
CCU hardcheck detected (CCU to MOSS status A
register, X'11', bit 6).
Upon detection of this event, MOSS will automat-
ically start a CCU automatic re-IPL. See Specific
Mechanism, page 11-12
NCP re-IPL
01
07
MOSS TRSS interface
NO
NO
01
08
CADS dump function
NO
NO
01
09
Address exception check in CCU (CCU to MOSS
status A register, X'11', bit 5)
MOSS
down
NO
03
01
0A
MOSS/MIOC operation check, CCU detected (CCU
to MOSS status A register, X'11', bit 7)
MOSS
down
NO
03
02
any
CCU logical interface
MOSS
down
NO
03
Chapter 11. Error Logging
11-33
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...