MOSS BER (ID 06)
Table 11-27 (Page 3 of 5). MOSS BER Type 01 ID 06 Field Details
Field Name
Bit Pattern
or
Hex Value
Meaning
DISK byte 1
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
. . . .
. . . .
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
Unused
Full instruction test load module
IOC bus tests load module
CLDP load module
Scanner load module
Scanner load module member 1
Scanner load module member 2
Scanner load module member 3
DISK byte 2
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
. . . .
. . . .
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
HPTSS/ESS load module
HPTSS/ESS load module member 1
HPTSS/ESS load module member 2
HPTSS/ESS load module member 3
SALT load module
Stand alone utilities
Port swap file
Unused
DISK2
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
. . . .
. . . .
x . . .
. . . .
. x . .
. . . .
. . xx
5 bytes, same allocation as 'halfwords' above
Roll in/out file
LSR file
CCU dump file
First dump record file
Last dump record file
Control program load module file
Unused
F2 byte 1
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
. . . .
. . . .
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
Bad branch trace buffer length
Bad check record pool
Bad control program interface table
level 1 on CA during CA monitoring
X71 register is not readable
CLDP did a pseudo abend
Loading scanner table failed (phase 3)
Control info length error: MB error
F2 byte 2
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
. . . .
. . . .
x . . .
. . . .
. x . .
. . . .
x x . .
. . . .
. . x .
. . . .
. . . x
IPL from disk length error: MB error
IPL complete with port swap errors
LSSD dump incorrect
Adapter dump requested, not performed
(bad return from CHGCDLA access function)
Error during save on disk
Error during load from disk
Error during reset active load mode
Error during dump on disk (phase 4)
Error during roll-in roll-out of top 64K of storage
to/from HDD
X71
X71 register
X72
X72 register
IPL mode
x . . .
. . . .
. x . .
. . . .
. . xx
. . . .
. . . .
x . . .
. . . .
. xxx
IPL mode (IPLMODE)
x = 0 <==> Operator
x = 1 <==> Automatic
Customer / maintenance (MTMENU)
x = 0 <==> Customer
x = 1 <==> Maintenance
Unused
Standalone dump status
x = 0 Not requested or failed
x = 1 Successfully performed
Unused
11-70
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...