ESS BER
Table 11-53 (Page 2 of 4). ESS BER Type 08 Summary
BER
ID
Abend
Code
(NCP)
Event Description
Recovery
or
Action
ALERT
ALARM
91
ELAyy AIO Error
IOC Error LVL1 with:
LVL1 Summary Register X7E = '0100' (IOC-1) with
IOC LVL1 Register X76 = 'uV00' (IOC-1) with
AIO CCW Register
X75H or X75L = B'1nnn n000' where nnnn from 0 to
15 represents the IOC relative adapter number, adapter which was
performing the AIO, AIO (Adapter Initiated Operation / Cycle Steal)
failing in Time-Out (V='A') or in Bus-In parity Check (V='6') with 'u' giving
the time when the operation failed (refer to page 2-34).
ELA
µ
code
retry
No
No
91
ELAyy AIO Error (threshold) Adapter Down flag is on.
ELA
down
34
34
92
ELAyy Unresolved AIO Error
IOC Error LVL1 with:
LVL1 Summary Register X7E = '0100' (IOC-1) with
IOC LVL1 Register X76 = 'uV00' (IOC-1) with
AIO CCW Register X75H or X75L = B'1nnn n000'
where nnnn from 0 to 15 represents the IOC relative adapter number,
adapter which was performing the AIO, but as opposed to previous BER
08 91, V='2' only (not 'A' or '6').
ELA
µ
code
retry
No
No
92
ELAyy Unresolved AIO Error (threshold) Adapter Down flag is On
ELA
down
34
34
93
ELAyy AIO Invalid CSCW
IOC Error LVL1 with:
LVL1 Summary Register X7E = '0100' (IOC-1) with
IOC LVL1 Register X76 = '2200' (IOC-1)
AIO CCW register X75H or X75L = B'1nnn n000' where nnnn from 0 to
15 represents the IOC relative adapter number, adapter which was per-
forming the AIO.
ELA
µ
code
retry
No
No
93
ELAyy AIO Invalid CSCW (threshold) Adapter Down flag is On
ELA
down
38
38
94
ELAyy Portx Cycle Steal Error on Set Mode
Adapter LVL1 with:
LVL1 Summary Register X7E = '2000' (IOC-1)
Adapter Status Register (Error Status Type 3 non-Hardstop) or
LAS = B'1000 0000 10xx xxxz' (almost identical to BER 08 1C as
Command Reject on line interface address 'xxxxxz') but NCP looks at the
SLI bit in the LNVT: if ON (Set LNVT Initial required) and if adapter
command-reject status = '10xx xxxx xxxx xxxx' then NCP will generate this
BER 08 94 instead of BER 08 1C.
Port
down
3C
3C
95
ELAyy Adapter LVL1 Hardcheck
Adapter LVL1 with:
LVL1 Summary Register X7E = '2000' (IOC-1) with Adapter Status Reg-
ister (Error Status Type 3 Hardstop) or
LAS = B'0000 0uuu
uuuu uu00' where the string 'uu..uu' reflects the
hardware checkers which have been raised (u=1), as several can occur
simultaneously in some cases of failure.
ELA
down
34
34
96
ELAyy Adapter Disconnected by operator
Adapter LVL1 with:
LVL1 Summary Register X7E = '2000' (IOC-1) with Adapter Status Reg-
ister (Error Status Type 3 non-Hardstop) or
LAS = B'1000 0001 0000 0000', meaning "adapter put in disconnect
mode" on MOSS operator's request.
ELA Off
line
3D
3D
11-134
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...