POWER BER
D1
The dump was possible.
D2
The dump already existed.
D3
The dump failed.
The REQ values are given in the following table.
BER caused by an event in the power area.
RESP field meaning depends on the associated REQ field value.
A REQ value corresponds to 2 possible RESP:
– OK response
– KO response
according to the following table:
Note: The REQUEST code is valid only when the BER is issued after a
MOSS request to the power control.
Table 11-50. BER 04 REQ/RESP Table for Power Dump
REQ
Requested by
Meaning
01
PCC
Invalid power ON
02
PCC
Invalid power OFF
03
PCC
Invalid power ON reset
04
PCC
Invalid interrupt level 0
05
PCC
Invalid interrupt level 1
06
PCC
Invalid interrupt level 2
81
PCC
Invalid power ON, dump stacked
82
PCC
Invalid power OFF, dump stacked
83
PCC
Invalid power ON reset, dump stacked
84
PCC
Invalid interrupt level 0, dump stacked
85
PCC
Invalid interrupt level 1, dump stacked
86
PCC
Invalid interrupt level 2, dump stacked
11
MOSS
Power microcode error
12
MOSS
PCC ckeck bad return
20
Operator
Manual request, via power services
Table 11-51 (Page 1 of 2). BER 04 REQ/RESP Table
REQ
RESP
OK
RESP
KO
Meaning
01
42
C2
Start diskette
02
43
C3
Stop diskette
05
N/A
N/A
MPWL reset
07
48
C8
Start disk
08
49
C9
Stop disk
09
4A
CA
Set adapter
0A
4B
CB
Reset adapter
0C
4E
N/A
Check MPWL
0D
50
N/A
Get end of IML data
0E
51
N/A
Get stacked error record
12
55
N/A
Set time of day
13
56
D6
Get time of day
14
57
N/A
Set scheduled power ON
15
58
N/A
Get scheduled power ON
16
59
N/A
Allow scheduling
17
5A
N/A
Inhibit scheduling
1B
5E
N/A
Get scheduling state
1F
70
F0
Display message indicator on panel
20
76
F6
Display console in use
21
7E
FE
Display hexadecimal code on panel
Chapter 11. Error Logging
11-129
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...