MOSS BER (ID 03)
Notes:
1. All values are in hexadecimal notation (X'0' to X'F'), except for the file name or
module name (FILE), which is in EBCDIC.
2. The CAC will make several retries (up to 10). The retry count contains the
number of retries before the disk operation was successfully terminated.
If RCNT is lower than 10, the last I/O operation was successful. The error
was intermittent.
If RCNT = 10, the decision (recovery or program action) is taken by the
MOSS application that activated the diskette operation. The error is perma-
nent (solid).
Table 11-18 (Page 2 of 2). MOSS BER Type 01 ID 03 Field Details
Field
Name
Bit Pattern
or
Hex Value
Meaning
SSB
byte 0
1 . . .
. . . .
. 1 . .
. . . .
. . 1 .
. . . .
. . . 1
. . . .
. . . .
1 . . .
. . . .
. x x .
. . . .
. . . 1
Drive status
Drive ready
Seek end (HDD only)
Write protected (FDD only)
Write fault (HDD only)
Disk change
Unused
Track 0
SSB
byte 1
x . . .
. . . .
. 1 . .
. . . .
. . 1 .
. . . .
. . . 1
. . . .
. . . .
1 . . .
. . . .
. 1 . .
. . . .
. . 1 .
. . . .
. . . 1
SSB error status byte 0
CRC/ECC error
x = 0: Data
x = 1: ID
CRC/ECC error
Address mark not found
Bad track
Wrong cylinder
Control address mark
Format error
ID not found
SSB
byte 2
x . . .
. . . .
. 1 . .
. . . .
. . 1 .
. . . .
. . . 1
. . . .
. . . .
xxxx
SSB error status byte 1
Unused
Data adapter error
Retry corrected
Defective sector
Unused
SSB
bytes 3-6
Last data adapter ID field processed
SSB
bytes 7-8
Cylinder and head location
SSB
byte 9
Number of sectors corrected by ECC
SSB
byte 10
Number of retries
SSB
byte 11
Processor state at reset time
11-58
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...