Power ON/OFF Sequence
Power ON Sequence
The normal power ON sequence is initiated by:
Manual power ON at the control panel if the machine is in local or network mode.
Power pick command (from one attached host) if the machine is in host mode.
Automatic restart function on an AC main utility failure if the machine was powered ON in host or
network mode when the failure occurred.
Scheduled power ON function if the machine is in network mode.
The PCC card first activates the reset lines of all the adapters
Then the main contactor command signal will turn ON the power supplies.
Then the LED driver out signal is activated.
After a 1 second wait the PCC checks the fault signals (overcurrent (OC) and power supply (PS) faults) of
both power supplies. If no fault, the reset lines are deactivated 100 ms later.
Then the disk (HDD) and the diskette (FDD) are powered ON.
MOSS IML will start, and at the end of IML the MOSS will ask the PCC card which type of power ON was
done (local, host, network, scheduled, automatic restart), the power ON time and the last power OFF time.
At the end of the power ON sequence, and if the machine is in host mode, the sequence complete signal
is sent to the host.
Note: When the machine is in local or network mode, this signal is forced permanently, whether the
machine is power ON or OFF.
In host or network mode, if there is a fault on a power supply, the power ON sequence is stopped, the
PCC deactivates the AC via the main contactor command signal, waits ten seconds and then re-issues
another power ON sequence. This is done two more times before the final power OFF.
10-22
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...