CA Services
Refer to the
Service Functions, SY33-2069, for more details.
The command Out X'07' from MOSS with bit 0.2 = 1 is provided to select a speci-
fied CA in order to enable CA services from MOSS. This function allows to:
Display CA status.
Display interface test points.
Enter host attachment information at installation time.
Issue specific commands to the CA, such as:
– Start/stop trace
– Dump
– Display storage and registers
– Reset
– Initialization.
CA Interface Display
Refer to the
Advanced Operations Guide, SA33-0097, for more details.
As soon as the local console is powered ON, the CA interface display screen
appears. This screen can also be displayed by selecting the channel interface
display (CID) function from MOSS menu 2.
The information displayed is:
Host attachment information
NSC address
MOSS enable/disable request
Interface status (enabled/disabled).
The CID screen also allows to modify the enable/disable request.
CA Initialization
The CA initialization is performed when a CA receives a POR signal, either at
general power ON, or through the MOSS 'Reset' command.
Initialization First Part (Checkout)
At checkout completion, the CA is in the following state:
1. IOC bus interconnection enabled.
2. MOSS interconnection enabled.
3. Host interfaces disabled.
The results of the checkout are available to the MOSS microcode.
7-24
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...