3746-900 BER
Table 11-55 (Page 3 of 4). 3746 Model 900 BER Type 9 Summary
BER
ID
Abend
Code
(NCP)
Event Description
Recovery
or PGM
Action
MOSS
ALERT
ALARM
38
Protocol hardware/software mismatch
LVL2 with cc = '03'
Line down
No but
NCP
alert
F0
39
Line NDPSA error
Diagnostic code = '04' for No ECB in NDPSA to pint on
PIU NPSA diagnostic code = '05' for invalid offset or
count in buffer prefix
Line down
No but
NCP
alert
F2
93
DMA Hardware Error
X7E='2000' (IOC-1 with CBA-1) or '0200' (IOC-2 with
CBA-2)
CBA LVL1 with first GES = X'3702', second GES =
SLID bytes 0-1, third GES = SLID bytes 2-3
CBA down
E7
E7
94
HPPB Hardware Error
X7E='2000' (IOC-1 with CBA-1) or '0200' (IOC-2 with
CBA-2)
CBA LVL1 with GES-1st = X'1100'
CBA down
E6
E6
95
Adapter program reset issued by NCP level 1 failed
twice (IOC error).
X7E='0100' (IOC-1 with CBA-1) or '0001' (IOC-2 with
CBA-2)
None
No
No
96
SAP to MOSS-E connection lost
X7E='2000' (IOC-1 with CBA-1) or '0200' (IOC-2 with
CBA-2)
CBA LVL1 with GES-1st = X'1300'
None
F7
F7
97
IOC PIO Error
LVL1 entered after NCP IOH instruction due to X7E =
'0100'(IOC-1/CBA-1) or '0001'(IOC-2/CBA-2) and X76 =
'x8' or 'x4'
NCP retry
No
No
98
IOC PIO Error (threshold)
Identical to BER 09 97
CBA down
E6
E6
99
Adapter LVL1-Invalid Error Status
X7E='2000' (IOC-1 with CBA-1) or '0200' (IOC-2 with
CBA-2)
CBA down
E8
E8
9B
IOC Error on PIO Set Hi/Lo Cmd
As BER 09 98(97) but on specific IOH commands
CBA down
E6
E6
9C
PIO Get Line ID failed
None.
No
No
9C
PIO Get Line ID failed or PIO GLID failed (threshold)
CBA down
E6
E6
9D
CDF-E update error
When CBA LVL1 with first GES = '43xx' as adapter
CDF-E update inconsistent, second GES = adapter
CDF-E entry bytes 0-1, third GES = adapter CDF-E
entry byte 3-4, and so on according to xx as a multiple
of 2.
X7E='2000' (IOC-1 with CBA-1) or '0200' (IOC-2 with
CBA-2)
CSS
adapter
down
EE
EE
9E
IOC PIO Error on GES
CBA down
E6
E6
Chapter 11. Error Logging
11-147
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...