ESS BER
NCP ESS BER Type 08
ESS BER Type 08 - Summary
Table 11-53 (Page 1 of 4). ESS BER Type 08 Summary
BER
ID
Abend
Code
(NCP)
Event Description
Recovery
or
Action
ALERT
ALARM
14
0930
ELAyy AIO Address Exception Check
IOC error LVL1 with:
LVL1 summary register X7E = '0100' (IOC-1) with
IOC LVL1 register X76 = '8200' (IOC-1)
NCP
re-IPL
No
E1
16
0931
ELAyy AIO Storage Protect Check
IOC Error LVL1 with:
LVL1 Summary Register X7E = '0100' (IOC-1) with
IOC LVL1 Register X76 = '4200' (IOC-1)
NCP
re-IPL
No
E1
18
ELAyy IOH/IOHI to Adapter not attached
IOC Error LVL1 with:
LVL1 Summary Register X7E = '0100' (IOC-1) with
IOC LVL1 Register X76 = '2800' (IOC-1)
For adapter address in TA, the CDS shows the adapter not attached.
None
30
30
1B
0933
ELAyy Invalid Input IOH
IOC Error LVL1 with:
LVL1 Summary Register X7E = '0100' (IOC-1) with
IOC LVL1 Register X76 = '5800' (IOC-1)
LAS (line adapter status) bit 1.7 is On.
NCP
re-IPL
No
E1
1C
ELAyy Portx Command Rejected by Adapter Microcode
Adapter LVL1 with:
LVL1 Summary Register X7E = '2000' (IOC-1) with
Adapter Status Register (Error Status Type 3 non-Hardstop) or
LAS = B'1000 00u0 10xx xxxz' as command reject on line interface
address = b'xxxxxz' where 'x..x' reflects the relative line address and 'z'
gives the interface side (Xmit or Rcv). When 'u' = 1 this indicates a
command reject for command-on-command.
Port
down
31
31
1E
ELAyy Invalid Output IOH to Adapter
Adapter LVL1 with:
LVL1 Summary Register X7E = '2000' (IOC-1) with
Adapter Status Register (Error Status Type 3 non-Hardstop) or
LAS = B'1000 000u 0100 0000' as Invalid Output IOH for which the
related PIO terminated correctly (no IOC error LVL1) but the adapter
microcode rejects the Output IOH by raising this current adapter LVL1.
'u' = '1' means adapter disconnected due to NCP command 'F2'.
ELA
down
32
32
26
ELAyy Portx SCTL/DMA Storage Protect or Address Exception
Adapter LVL2 with:
PSA LCS (Line Control Status) = 'DC' as any DMA type error
PSA HELCS (High byte of Extended LCS) = '10' as specifically SP/AE
ELA
port
down
37
37
Chapter 11. Error Logging
11-133
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...