TSS/HPTSS BER
TSS/HPTSS BER Type 11 - Field Description
Table 11-62 (Page 1 of 2). TSS/HPTSS BER Type 11 Field Description
Field
Name
Meaning
Refer to
ADNO
CS number (decimal) in error description field. This CS
number is derived from:
field TA for PIO operation
– for CS error reported at level 2
– for CA error reported at level 3.
field X75 for AIO operation.
field CSPA for CS error reported at level 1.
If no n is specified (blank CS), problem isolation by
program was not possible.
LAS or
L-STAT
LA adapter status
LA Error status type 1: CSP error status 1
LA Error status type 2: CSP error status 1
LA Error status type 3/H: CSP error status 1
Chapter 4
CSPA
CSP address used by NCP/PEP (see CSn and LINEnn).
ETA
TA field of IOH failure in level 1.
IDR
Get line ID response.
Chapter 4
F
Indicator flag (indicates a byte expansion follows)
(*)
SWA
Unused
CR1
First command sent to scanner
CR2
Second command sent to scanner
LAR
Lagging address register-
Page 2-42
SPR
LA shared pointer register X'3F' or X'6F'.
CSC
Configuration status control flag (contains X'FFFF' for
PEP, BSC/SS and BNN lines).
CNT
Repetition count (BER flooding). Number of times the
BER appeared.
SCF
Secondary control field.
I
First two bytes of instruction.
IAR
IAR of interrupt level.
LCS
Line control status.
Chapter 4 and
page 5-31
LINEnn
Line number (0 to 31) within the CS (in error description
line).
LNVT
Line vector table.
Chapter 4
LOST
Lost record count (LRC).
(*)
NW
Network address (NCP) or CA number and ESC (PEP).
(*)
IOB/LXB
X'24' bytes of LXB (for SDLC lines) or IOB (for BSC/SS
lines) control blocks. This area is padded with X'FF' for
PEP.
(*)
CCB
X'40' bytes of data from the CCB control block.
If PEP, the fields are CCBL2 through CCBPOLL inclu-
sive.
If PEP, the fields are CCBTROPT through CCBXPTR
inclusive.
(*)
AXB ACB
TRACE
X'E' bytes of data from the AXB control block from
AXBFCTL through AXB+X'15' (ACB trace area).
For PEP, this area contains the CCB extension starting at
the PEP CCB + X'60'.
(*)
AXB PSA
X'11' bytes of data from the PSA trace area of the AXB
control block (AXBASSCF through AXBTROFF).
For PEP, this area contains the remaining portion of the
CCB extension padded with X'F'.
(*)
SCB
X'19' bytes of the SCB/CUB from SCBSSCF (CUBSSCF)
through SCBRTCNT (CUBRTCNT) inclusively. For
BSC/SS lines and for PEP, this area is padded with
X'FF's.
(*)
Chapter 11. Error Logging
11-187
Содержание 3745 Series
Страница 2: ......
Страница 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Страница 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Страница 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Страница 255: ...The HPTSS in 3745 Models 130 150 160 and 170 Data Flow Chapter 5 High Performance Transmission Subsystem HPTSS 5 3 ...
Страница 303: ...Figure 6 8 Ring to Ring via Bridge Example 2 Typical Multi Floor Wiring Chapter 6 The Token Ring Subsystem 6 9 ...
Страница 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Страница 668: ...Problem Determination Aid 12 46 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Страница 708: ......
Страница 711: ......
Страница 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...