6-64
TEST PROCEDURE
Test 17 : Check voltage at CN-53 (23)
and ground.
Prepare 1 piece of thin sharp pin, steel or
copper.
Inser t prepared pin to rear side of
connectors : One pin to (23) of CN-53.
Starting switch ON.
Check voltage as figure.
MCU
CN-53
CN-53
Female
1
2
3
4
5
6
7
8
9
10
31
32
33
34
36
37
38
39
40
11
21
20
30
Multimeter
GROUND
PIN
23
(1)
刮
刯
到
刱
2)
SPEC : Actuator operating : 1~5 V