![Hyundai HX430L Скачать руководство пользователя страница 423](http://html1.mh-extra.com/html/hyundai/hx430l/hx430l_manual_2196358423.webp)
7-19
Monitoring
(analog)
Cluster
Pressure sensor
Main pump
a2
a1
Preparation
Keep the hydraulic oil temperature at
50
佳
5˚C.
Measurement
Select the following switch positions.
Power mode switch : P mode
Slowly operate each control lever of
boom, arm and bucket functions at full
stroke over relief and measure the
pressure.
In the swing function, place bucket
against an immovable object and
measure the relief pressure.
In the travel function, lock undercarriage
with an immovable object and measure
the relief pressure.
Evaluation
(1)
刮
(2)
刮
余
刯
到
刱
SYSTEM PRESSURE REGULATOR RELIEF SETTING
16)
The average measured pressure should be within the following specifications.
(3)
Unit : kgf / cm
2
( ) : Power boost
330L7MS03
Model
Function to be tested
Standard
Port relief setting
HX430 L
Boom, Arm, Bucket
330 (360)
Ü
10
390
Ü
10
Travel
360
Ü
10
-
Swing
290
Ü
10
-
Содержание HX430L
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10 ...
Страница 161: ...4 6 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV ...
Страница 205: ...4 50 No of pin Receptacle connector female Plug connector male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13 ...
Страница 528: ...8 88 Assemble relief valve assy 45 using torque wrench ÂTightening torque 26Ü2 6 kgfÂm 188Ü18 8 lbfÂft 31 43098TM95 ...
Страница 548: ...8 108 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10 ...
Страница 559: ...8 119 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10 ...
Страница 589: ...8 149 1 STRUCTURE GROUP 11 WORK EQUIPMENT B SECTION C SECTION B SECTION A C C A B A 21078DA 44 ...