7-15
Unit : mm
CONTROL LEVER STROKE
Measure each lever stroke at the lever top
using a ruler.
When the lever has play, take a half of this
value and add it to the measured stroke.
Preparation
Keep the hydraulic oil temperature at
50
Ü
5˚C.
Measurement
Stop the engine.
Measure each lever stroke at the lever
top from neutral to the stroke end using a
ruler.
Repeat step
刯
three times and calculate
the average values.
Evaluation
12)
(1)
侍
(2)
(3)
刮
刯
到
The measured drift should be within the following specifications.
(4)
Model
Kind of lever
Standard
Maximum allowable
Remarks
HX430 L
Boom lever
90
Ü
10
115
Arm lever
90
Ü
10
115
Bucket lever
90
Ü
10
115
Swing lever
90
Ü
10
115
Travel lever
142
Ü
10
178