6-32
9. WHEN FUEL GAUGE DOES NOT OPERATE (HCESPN 301, FMI 3 or 4)
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
CN-51
MCU
5
CN-52
26
CD-2
2
1
FUEL LEVEL SENDER
Cause
Remedy
Defective MCU or
cluster
Disconnection in
wiring harness or
poor contact
between fuel
sender-MCU
Defective fuel
sender
Replace
Repair or replace
Replace
YES
YES
Starting switch : OFF
Spec : 50~600
̫
See table
Check resistance
between fuel
sender (1) and
(2)
Check resistance
between CN-51
(5) and CN-52
(26)
Starting switch : OFF
Disconnect CN-51, 52
Spec : 50~600
̫
NO
NO
300L6ES10
Check Table
Range
Resistance (
̫
)
Range
Resistance (
̫
)
Full
50
5/12
400
11/12
100
4/12
450
10/12
150
3/12
500
9/12
200
2/12
550
8/12
250
1/12
600
7/12
300
Empty warning
700
6/12
350
-
-
Содержание HX430L
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10 ...
Страница 161: ...4 6 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV ...
Страница 205: ...4 50 No of pin Receptacle connector female Plug connector male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13 ...
Страница 528: ...8 88 Assemble relief valve assy 45 using torque wrench ÂTightening torque 26Ü2 6 kgfÂm 188Ü18 8 lbfÂft 31 43098TM95 ...
Страница 548: ...8 108 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10 ...
Страница 559: ...8 119 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10 ...
Страница 589: ...8 149 1 STRUCTURE GROUP 11 WORK EQUIPMENT B SECTION C SECTION B SECTION A C C A B A 21078DA 44 ...