2-72
GROUP 5 RCV LEVER
1. STRUCTURE
The casing has the oil inlet port P (primary pressure) and the oil outlet port T (tank). In addition the
secondary pressure is taken out through ports 1, 2, 3 and 4 provided at the bottom face.
ö
Refer to the parts manual for the types of the RCV lever.
VIEW A-A
4
1
T
2
3
P
P
3
T
4
1
2
LH
Hydraulic circuit
TYPE L1, L3
5
A
A
19
Single
operation
25
Simultaneous
operation
2
3
T
1
P
4
RH
6
5
6
TYPE L5
8
7
Null
Null
300L2RL01
Switches
Type
No.
LH
RH
L1, L3
5
One touch decel
Horn
6
Power boost
Breaker
L5
5
One touch decel
Horn
6
Power boost
Null
7
CCW rotation
Close
8
CW rotation
Open
Pilot ports
Port
LH
RH
Port size
P
Pilot oil inlet port
Pilot oil inlet port
PF 3/8
T
Pilot oil return port Pilot oil return port
1
Left swing port
Bucket out port
2
Arm out port
Boom up port
3
Right swing port
Bucket in port
4
Arm in port
Boom down port
TYPE L1, L3, L5
1)
ö
Number 7 and 8 : Option attachment
Содержание HX430L
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10 ...
Страница 161: ...4 6 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV ...
Страница 205: ...4 50 No of pin Receptacle connector female Plug connector male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13 ...
Страница 528: ...8 88 Assemble relief valve assy 45 using torque wrench ÂTightening torque 26Ü2 6 kgfÂm 188Ü18 8 lbfÂft 31 43098TM95 ...
Страница 548: ...8 108 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10 ...
Страница 559: ...8 119 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10 ...
Страница 589: ...8 149 1 STRUCTURE GROUP 11 WORK EQUIPMENT B SECTION C SECTION B SECTION A C C A B A 21078DA 44 ...