3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-72
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
Message
Severity Description
Action
A diagnostic interrupt has
occurred on system %1.
(
%1 =
CIM_ComputerSystem.
ElementName
)
Error
An operator information panel
NMI/diagnostic interrupt has
occurred
If the NMI button on the operator
information panel has not been
pressed, complete the following
steps:
1. Make sure that the NMI
button is not pressed.
2. Replace the operator
information panel cable.
3. Replace the operator
information panel.
A bus timeout has
occurred on sys- tem %1.
(
%1 = CIM_ComputerSystem
.ElementName
)
Error
A bus timeout has occurred.
1. Remove the adapter from the
PCI slot that is indicated by a lit
LED.
2. Replace the adapter.
3. Remove all PCI adapters.
4. (Trained service technicians
only) Replace the I/O board.
A software NMI has
occurred on sys- tem %1.
(
%1 = CIM_ComputerSystem
.ElementName
)
Error
A software NMI has occurred.
1. Check the device driver.
2. Reinstall the device driver.
The System %1 encountered
a POST Error.
(
%1 = CIM_ComputerSystem
.ElementName
)
Error
A POST error has occurred.
(Sensor = ABR Status)
1. Recover the server
firmware from the backup page
(see “Recovering the server
firmware”).
2. Update the server firmware
to the latest level.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update the code