3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-82
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
Message
Severity Description
Action
Array in system %1 is in
critical con- dition.
(
%1 =
CIM_ComputerSystem.
ElementName
)
Error
An array is in Critical state.
(Sensor = Drive
n
Status)
(
n
= hard disk drive number)
Replace the hard disk drive that
is indicated by a lit status LED.
Array in system %1 has
failed.
(
%1 = CIM_ComputerSystem
.ElementName
)
Error
An array is in Failed state.
(Sensor = Drive
n
Status)
(
n
= hard disk drive number)
Replace the hard disk drive that
is indicated by a lit status LED.
Failure predicted on Drive
1 Status for array SN#
ZZZZZZP.
Warning
A drive is about to fail.
Replace the hard disk drive that
is indicated by a lit status LED.
Memory Errors
NOTE
A DIMM error message indicates the DIMM, but not the memory card, on which the error has
occurred.
DIMMs 1 - 8 are on memory card 1, DIMMs 9 - 16 are on memory card 2, and so on.
Memory Expansion Unit 1 was
detected as absent.
Info
The memory expansion unit was
detected as absent when it was
expected to be present.
Check the QPI cable
connections, then reboot the
server to see if it recovers.
Memory Expansion Unit 1
detected as present.
Info
The memory expansion unit was
detected as present when it was
expected to be absent.
Check the QPI cable
connections, then reboot the
server to see if it recovers.
Uncorrectable error detected
for all DIMMs on
Subsystem System
Memory.
Error
A memory uncorrectable error
has occurred.
1. If the server failed the
POST memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note:
You do not have to replace
DIMMs by pairs.
3. Run the Setup utility to
enable all the DIMMs.
4. Run the memory test. (This
test might take up to 30 minutes
to run.)