3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-70
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
Message
Severity Description
Action
An SMBIOS Uncorrectable
CPU complex error for
Processor n has asserted. (n =
microprocessor number)
Error
The system management handler
has detected an internal
microprocessor error.
1. Check for a server
firmware update.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
2. Make sure that the installed
microprocessors are compatible
with each other (see
“Microprocessor” for
information about
microprocessor requirements).
3. (Trained service technician
only) Reseat microprocessor
n
.
4. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
Sensor CPU n
OverTemp has transitioned
to critical from a less
severe state. (n =
microprocessor number)
Error
A sensor has changed to Critical
state from a less severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffles are in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat
sink for microprocessor
n
is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)