Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-29
time, in the order shown, restarting the server
each time:
a. Battery
b. Failing device (if the device is a FRU, it must
be replaced by a trained service technician
only)
c. (Trained service technician only) I/O-board
shuttle
3058004
Three boot failures
1. Undo any recent system changes, such as
new settings or newly installed devices.
2. Make sure that the server is attached to a
reliable power source.
3. Remove all hardware that is not listed on the
ServerProven Web site.
4. Make sure that the operating system is not
corrupted.
5. Run the Setup utility, save the configuration,
and then restart the server.
3108007
System
configuration
restored to default settings
Information only. This is message is usually
associated with the CMOS battery clear event.
3138002
Boot configuration error
1. Remove any recent configuration changes
that
you made in the Setup utility.
2. Run the Setup utility, select
Load Default
Settings
, and save the settings.
3808000
Error
updating
system
configuration to IMM
3808002
Error
updating
system
configuration to IMM
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup utility and select
Save
Settings
.
3. Update the firmware.
3808003
Error
retrieving
system
configuration from IMM
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup utility and select
Save
Settings
.
3. Update the IMM firmware.
3808004
IMM system event log full
When out-of-band, use the IMM Web
interface or IPMItool to clear the logs