Message
Severity Description
Action
Sensor VT Fault has
transitioned to non-recoverable.
Error
A sensor has changed to
Nonrecoverable state
1. Check the power-supply
LEDs.
2. Follow the actions in
“Power-supply LEDs”.
3. Replace the failing power
supply.
4. (Trained service technician
only) Replace the I/O-board
shuttle.
Sensor VT Fault has
transitioned from normal to
non-critical state.
Warning
A sensor has transitioned to a
non-critical state.
No action; information only.
Sensor P wr Rail A
Fault has transitioned to
non-recoverable.
Error
A sensor has changed to
Nonrecoverable state.
1. Turn off the server and
disconnect it from power.
2. (Trained service technician
only) Remove the
microprocessor from socket 1.
Note:
The server will not
start when no microprocessor is
installed in socket 1.
3. Reinstall the
microprocessor in socket 1 and
restart the server.
4. (Trained service technician
only) Replace the failing
microprocessor.
5. (Trained service technician
only) Replace the microprocessor
board.
Sensor Pwr Rail B
Fault has transitioned to
non-recoverable.
Error
A sensor has changed to
Nonrecoverable state.
1. Turn off the server and
disconnect it from power.
2. (Trained service technician
only) Remove the
microprocessor from socket 2.
Note:
The server will not
start when no microprocessor is
installed in socket 1.
3. Reinstall the
microprocessor in socket 2 and
restart the server.
4. (Trained service technician
only) Replace the failing
microprocessor.
5. (Trained service technician
only) Replace the microprocessor
board.