3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-80
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
Message
Severity Description
Action
Redundancy lost for
Cooling Zone 1
has asserted.
Error
Redundancy has been lost and is
insufficient to continue operation.
1. Make sure that the
connectors on fans 1 and 3 are
not damaged.
2. Make sure that the fan
connectors 1 and 3 on the
microprocessor board are not
damaged.
3. Make sure that the fans are
correctly installed.
4. Reseat the fans.
5. Replace the fans.
Redundancy lost for
Cooling Zone 2
has asserted.
Error
Redundancy has been lost and is
insufficient to continue operation.
1. Make sure that the
connectors on fans 2 and 3 are
not damaged.
2. Make sure that the fan
connectors 2 and 3 on the
microprocessor board are not
damaged.
3. Make sure that the fans are
correctly installed.
4. Reseat the fans.
5. Replace the fans
Redundancy lot for Cooling
Zone 3
has asserted.
Error
Redundancy has been lost and is
insufficient to continue operation.
1. Make sure that the
connector on fan 3 is not
damaged.
2. Make sure that the fan 3
connector on the microprocessor
board is not damaged.
3. Make sure that the fan is
correctly installed.
4. Reseat the fan.
5. Replace the fan.
Non-redundant: Insufficient
resources for Cooling Zone
1 has asserted.
Warning
Redundancy is insufficient and
might degrade or interrupt
system operation.
1. Make sure that the
connectors on fans 1 and 3 are
not damaged.
2. Make sure that fan
connectors 1 and 3 on the
microprocessor board are not
damaged.
3. Make sure that the fans are
correctly installed.
4. Reseat the fans.
5. Replace the fans.