Message
Severity Description
Action
Sensor CPU n
OverTemp has transitioned
to non-recoverable from
a less severe state. (n =
microprocessor number)
Error
A sensor has changed to
Nonrecoverable state from a less
severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffles are in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat
sink for microprocessor
n
is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
Sensor CPU n
OverTemp has transitioned
to critical from a non-
recoverable state. (n =
microprocessor number)
Error
A sensor has changed to Critical
state from Nonrecoverable state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffles are in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat
sink for microprocessor
n
is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
Sensor CPU n OverTemp
has transitioned to
non-recoverable. (n =
microprocessor number)
Error
A sensor has changed to
Nonrecoverable state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffles are in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat
sink for microprocessor
n
is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)