Tecal RH5485 Server
Problem Determination and Service Guide
3 Diagnostics
Issue 02 (2011-05-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-87
Message
Severity Description
Action
Fault in slot PCI n on
system SN# ZZZZZZP.
Error
A fault has occurred in PCI slot
n
.
1. Check the riser-card LEDs.
2. Reseat the affected
adapters.
3. Update the server and
adapter firmware (UEFI and
IMM).
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
4. Remove the adapter from
slot
n
.
5. Replace the PCI Express
adapter.
Non-redundant: Insufficient
resources for Backup Memory
has asserted.
Error
Redundancy Lost for Backup
Memory has asserted.
1. Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2. Re-enable mirroring in the
Setup utility.
Non-redundant: Sufficient
resources form Redundancy
Degraded or Fully Redundant
for Backup Memory has
asserted.
Error
Redundancy Lost for Backup
Memory has asserted.
1. Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2. Re-enable mirroring in the
Setup utility.
Sensor Mem Lane Spared
has asserted
Info
A recoverable error has occurred
on a memory card interface.
1. Check the system-event log
for memory card failure
events (uncorrectable or PFA)
and correct the failures.
2. Reseat the memory card.
3. Replace the failing memory
card.
Sensor Planar Fault has
transitioned to critical from
a less severe state.
Error
A sensor has changed to Critical
state from a less severe state.
(Trained service technician only)
Replace the microprocessor
board.