TIP:
When you put the storage system in maintenance mode or edit the maintenance mode,
specify the duration in hours and a reason.
To edit the maintenance window, select
Actions
>
Set maintenance mode
and then click
the Edit icon next to the maintenance window.
5.
Initiate
Check Health
on the storage system.
a.
From the Service Console interface, select
Systems
.
b.
Select
Actions
>
Check health
.
A check of the storage system runs to ensure that there are no additional issues.
CAUTION:
If health issues are identified during the
Check Health
, resolve these issues before
continuing. Refer to the details in the
Check Health
results and review the documentation.
6.
Review the information in the email alert notification.
If the email notifications are enabled, information about the failed port due to the failed SFP
transceiver is provided in an email alert notification. The port position in the storage system is
provided as Node:Slot:Port (N:S:P).
7.
Review the information in the HPE 3PAR Service Console (SC) alert notification.
An alert notification banner appears that contains the information for the failed port due to the failed
SFP. In the alert notification banner, the port position is provided as Node:Slot:Port (N:S:P). To
expand the box, click the banner, which shows additional information about the nature of the alert.
Click the details link to be taken to the
Activity
view for the appropriate component. You can also
view a graphical representation of the components from the
Schematic
view.
8.
Locate the failed SFP transceiver.
To locate the port containing the failed SFP transceiver, use the Node:Slot:Port position. The port has
a flashing green Link Status LED and the Port Speed LED is off.
Removal
9.
Label the cable connected to the failed SFP transceiver with the port location, and then disconnect
the cable.
10.
Remove the SFP transceiver.
CAUTION:
To prevent damage, do not touch the gold contact leads on the SFP transceiver.
a.
On the SFP transceiver, pivot open the retaining clip.
b.
Slide the SFP transceiver out of the port slot.
Replacement
11.
Install the SFP transceiver.
CAUTION:
To prevent damage, do not touch the gold contact leads on the SFP transceiver.
54