Cage cage:<cageid> "Missing A loop" (or "Missing B loop")
Cage cage:<cageid>,mag:<magpos> "Magazine is <MAGSTATE>"
Cage cage:<cageid> "Power supply <X>'s fan is <FANSTATE>"
Cage cage:<cageid> "Power supply <X> is <PSSTATE>" (Degraded, Failed, Not_Present)
Cage cage:<cageid> "Power supply <X>'s AC state is <PSSTATE>"
Cage cage:<cageid> "Cage is in "servicing" mode (Hot-Plug LED may be illuminated)"
Cage cage:<cageid> "Firmware is not current"
Cage cage:<cageid> "Cage type <Model> is not supported on this platform"
Cage cage:<cageid> "Missing both A and B loops"
Cage cage:<cageid> "Cage state information is unavailable"
cage
example 1
Component -Summary Description- Qty
Cage Cages missing A loop 1
Component -Identifier- -Detailed Description--
Cage cage:1 Missing A loop
cage
suggested action 1
cli%
showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model FormFactor
1 cage1 0:1:1 1 1:1:1 1 8 21-23 402e 402e DCS8 SFF
-----------Cage detail info for cage1 ---------
Position: ---
Interface Board Info Card0 Card1
Firmware_status Current Current
Product_Rev 402e 402e
State(self,partner) OK,OK OK,OK
VendorId,ProductId HP,DCS8 HP,DCS8
Master_CPU Yes No
SAS_Addr 50050CC1178EA0BE 50050CC1178E6BBE
Link_Speed(DP1,DP2) 6.0Gbps,Unknown 6.0Gbps,Unknown
PS PSState ACState DCState Fan State Fan0_Speed Fan1_Speed
ps0 OK OK OK OK Low Low
ps1 Failed Failed Failed OK Low Low
-------------Drive Info-------------- --PortA-- --PortB--
Drive DeviceName State Temp(C) LoopState LoopState
0:0 5000c500720387e0 Normal 21 OK OK
1:0 5000c50072039188 Normal 21 OK OK
2:0 5000c500720387b0 Normal 21 OK OK
3:0 5000c500720395b4 Normal 21 OK OK
4:0 5000c50072036fbc Normal 21 OK OK
5:0 5000c50072039fc0 Normal 21 OK OK
6:0 5000c50072037250 Normal 22 OK OK
7:0 5000c5005737cc0c Normal 23 OK OK
Check the connection/path to the SFP in the drive enclosure (cage) and the level of signal the SFP is
receiving. An RX Power reading below 100 µW signals the RX Power Low condition; typical readings are
between 300 µW and 400 µW. Helpful CLI commands are
showcage -d
and
showcage -sfp -ddm
.
At least two connections are expected for drive enclosures (cages), and this exception is flagged if that is
not the case.
cage
example 2