Figure 29: Removing the DC power cooling module, controller node enclosure
12.
Remove the battery from the DC PCM.
a.
At the back of the PCM, lift the battery release handle.
b.
Remove the battery from the battery compartment and place on the ESD safe mat.
Figure 30: Removing the battery, DC power cooling module, controller node enclosure
Replacement
13.
Install the battery in the DC PCM.
a.
With the battery handle in the upright position, insert the battery into the -48V DC PCM.
b.
Push down the handle to install.
When the battery is correctly seated, the battery and handle are aligned with the surface of the
-48V DC PCM.
Service