Node
Number
The AppleTalk Node Number that the print server chose for itself as part of its initialization
sequence.
Note: The AppleTalk phase 2 (P2) parameter is preconfigured on the print server.
Back to Top
DLC/LLC Protocol Information
Provides the current status for the DLC/LLC network protocol.
Message
Description
STATUS:
Indicates the current DLC/LLC protocol status.
READY: Indicates the HP Jetdirect print server is awaiting data.
DISABLED: Indicates that DLC/LLC was manually disabled.
INITIALIZING: Indicates that the print server is registering the node address or name. An
additional status message may also be displayed.
An
error code and message
are displayed if the print server is not ready.
Back to Top
Error Messages
Error Code and
Message
Description
02
LAN ERROR-
INTERNAL
LOOPBACK
During self-test, the print server detected an internal loopback test error. The print server
may be faulty. If the error persists, replace the print server.
03
LAN ERROR-
EXTERNAL
LOOPBACK
The print server is incorrectly connected to your network or is defective. Make sure your
print server is correctly attached to your network. In addition, check the cabling and
connectors.
07
LAN ERROR-
CONTROLLER
CHIP
Check the network connections. If the connections are intact, run the power-on self-test:
turn the printer off, then on again. If the error persists, replace the print server.
08
LAN ERROR-
INFINITE
DEFERRAL
There is a network congestion problem.
Note: If the print server is not connected to the network, this error cannot occur.
Содержание jetdirect 250m
Страница 12: ...Section 1 Networks Click the button to continue ...
Страница 21: ...Section 2 Network Printing Click the button to continue ...
Страница 28: ...Section 3 Installing a Network Printer Click the button to continue ...
Страница 37: ...End of Network Basics tutorial ...
Страница 82: ...Next topic Requirements ...
Страница 99: ...Next topic Other links ...
Страница 136: ...Next topic Using RARP ...
Страница 194: ...Does the control panel display on your printer show an error message ...
Страница 215: ...Does the page indicate I O Card Ready ...
Страница 218: ......
Страница 278: ...Australia This equipment complies with Australian EMC requirements Canada ...
Страница 280: ......