![HP E4401B Скачать руководство пользователя страница 256](http://html.mh-extra.com/html/hp/e4401b/e4401b_programmers-manual_161548256.webp)
5-102
Chapter 5
Language Reference
SOURce Subsystem
Default Unit:
dB
Front Panel
Access:
Source, Attenuation Auto Man
Automatic Source Attenuation
:SOURce:POWer:ATTenuation:AUTO OFF|ON|0|1
:SOURce:POWer:ATTenuation:AUTO?
Selects if the source output level attenuator will be set automatically.
Factory Preset
and *RST:
On
Front Panel
Access:
Source, Attenuation Auto Man
Sets the Output Power
:SOURce:POWer[:LEVel][:IMMediate][:AMPLitude] <ampl>
:SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]?
Specifies the source output power level. Use
:SOURce:POWer:SWEep
to
set the change in power level across the sweep. See also
:SOURce:POWer:STARt
.
Factory Preset
and *RST:
−
10 dBm
Range:
HP ESA E4401B, E4411B: –70 dBm to 3 dBm
HP ESA E4402B, E4403B: –66 dBm to 3 dBm
HP ESA E4404B: –66 dBm to 3 dBm
HP ESA E4405B: –66 dBm to 3 dBm
HP ESA E4407B, E4408B: –66 dBm to 3 dBm
Default Unit:
dBm
Front Panel
Access:
Source, Amplitude On Off
Sets the Source Output Power Mode
:SOURce:POWer:MODE FIXed|SWEep
:SOURce:POWer:MODE?
Sets the source output to be at a single amplitude (fixed) or to sweep
through a range of power levels.
Содержание E4401B
Страница 6: ...vi ...
Страница 14: ...xiv Contents ...
Страница 64: ...2 34 Chapter2 HP ESA Status Registers Using the Analyzer Status Registers ...
Страница 65: ...3 1 3 Programming Examples ...
Страница 118: ...3 54 Chapter3 Programming Examples Entering Amplitude Correction Data Close the session viClose viESA viClose defaultRM ...
Страница 151: ...4 1 4 Programming Command Cross References ...
Страница 286: ...5 132 Chapter5 Language Reference UNIT Subsystem ...
Страница 287: ...6 1 6 HP 8590 HP ESA Spectrum Analyzers Programming Conversion Guide ...
Страница 292: ...1 HP 8590 HP ESA Spectrum Analyzers Conversion Guide ...
Страница 368: ...7 1 7 Error Messages ...
Страница 393: ...7 26 Chapter7 Error Messages 201 to 799 Device Specific Errors ...