2.
If rack installed, slide the server out from the rack until it stops. See
.
3.
Unlatch the cover release lever on the top cover and remove the memory carrier assembly
cover. See
“Removing the Memory Carrier Assembly Cover” (page 179)
.
NOTE:
You do not need to fully remove the top cover to service this component; however,
the top cover release lever must be open.
4.
Remove the memory carrier assembly. See
“Removing the Memory Carrier Assembly”
NOTE:
To avoid damage to the extraction handles, Hewlett Packard Enterprise
recommends rotating the handles inward and snapping them the locked position when
servicing the system DIMMs or any time the carrier is out of the chassis. Before replacing
the memory carrier, press the button to release the extraction handles. Use the handles to
replace the memory carrier into the chassis.
5.
Complete the following memory installation prerequisite tasks before installing the memory:
a.
Determine the DIMM load order for the 48-DIMM memory carrier. For more information,
see
“Memory Load Order” (page 209)
.
b.
Determine the DIMM slots to populate. Use
Figure 70: “48-DIMM Memory Carrier Board
.
c.
Read, understand, and follow the general guidelines to install memory in the server.
See
“Memory Loading Rules and Guidelines” (page 210)
.
6.
Lay the memory carrier assembly on side 0 or side 1 so that the memory carrier side that
contains the DIMM slots that require servicing faces upward (
7.
Remove the memory carrier assembly side cover.
a.
Press the release tabs (
) on both sides of the extraction handle release button
until the side cover releases from the top center of the assembly.
b.
Rotate the side cover slightly to free the tabs from the retaining slots at the base of the
assembly (
).
c.
Lift the side cover off the assembly.
212
Removing and Replacing Server Components